+44-203-7693048
Home / Products / CONTROLLER / innoCon 6501 series / innoCon 6501CL Online Residual Chlorine Analyzer

innoCon 6501CL Online Residual Chlorine Analyzer

Measurement parameters

Residual chlorine



Features

● The latest wide power input, super anti-interference design
● Economical and practical
● Large-screen backlit LCD display, easy to read all day long
● Chinese / English menu, easier to operate
● Password protection, to prevent unauthorized operation
● 2 sets relay output can set High/ Low
● 1 channel 4-20mA current
● RS485 Modbus output



Features
Product Model: innoCon 6501CL
Measurement parameters: residual chlorine
Measuring range: 0 - 2.000ppm, 0 -20.00ppm
Resolution: 0.001/0.01ppm
Accuracy: ±2%f.s.
Temperature compensation: PT1000 or NTC10K
Display: backlit dot matrix LCD
Language: Chinese/English
Password: Setting mode: 0022, calibration mode: 0011
Power supply: 90-260VAC,50/60Hz; 24VDC optional
Current output: 1 x isolated 4-20mA output, measurable value can be set, maximum load 500Ω
Digital communication: RS485 Modbus RTU
Alarm output: 2 sets of programmable Hi/Lo contacts with hysteresis setting, 5A/250VAC/30VDC
Operating temperature: 0~70.0℃
Protection grade: IP65
Installation: panel/pipe
Size: 108 × 108 × 145mm
Opening size: 92 × 92mm
Weight: about 0.6Kg
Order No.: 33-6501-30




innoSens 710 chlorine residual/chlorine dioxide/ozone electrode

The innoSens 710 electrode is based on the principle of double platinum constant voltage measurement. The measuring and reference electrodes maintain a stable potential at which different measured constituents produce different current strengths. During the measurement process, Cl2 or HClO is consumed, so the current intensity generated is related to the concentration of residual chlorine in the water. When the pH value is in the range of 6-8, the measurement signal decreases as the pH value increases, which can be compensated for by inputting the pH value of the site. Chlorine dioxide and ozone can also be measured using the constant voltage method (innoCon 6800CL Smart Controller only).


Measuring range: 0-2.000/0-20.00ppm (mg/L)
Resolution: 0.001/0.01ppm
Accuracy: ±2%f.s.
Temperature compensation: PT1000 (optional)
pH compensation: 0-60°C
Working temperature: manual pH compensation
Suggested flow rate: 10-30l/h
Electrode material: glass
Thread connection: PG13.5
Cable length: standard 3m, optional 10m
Size: φ12mm×120mm
specifications
Order No.          Description

35-0710-00      innoSens 710 dual platinum electrodes, cable 3m

35-0710-10      innoSens 710 dual platinum electrodes, cable 10m

35-0710-20      PT1000 temperature probe for PA-711 flow-through tanks

50-0711-00       PA-711 flow cell, acrylic

download

innoCon 6501CL

QUESTIONS? WE'RE HERE TO HELP.

CONTACT US