Measurement parameters
Ion concentration
Features
● The latest wide power input, super anti-interference design
● Large-screen backlit LCD shows measured values, temperature and
relay status
● Chinese / English menu, easier to operate
● Password protection, to prevent unauthorized operation
● New calibration steps can help reduce operational errors
● 2 sets relay output can set High/ Low
● Automatic cleaning relay output
● 2 channel 4-20mA current
● RS485 Modbus output
Features
Product Model: innoCon 6800I
Measurement parameters: Ion concentration
Measuring range: 0 - 20000ppm
Resolution: 0.01/0.1/1ppm
Accuracy: ±5% f.s.
Temperature compensation: PT1000 or NTC10K
Display: backlit large dot-matrix liquid crystal display
Language: Chinese/English
Password: Setting mode: 0022, calibration mode: 0011
Power supply: 90-260VAC,50/60Hz; 24VDC optional
Current output: 2 x isolated 4-20mA outputs, can set the measured value and temperature, maximum load 500Ω
Digital communication: RS485 Modbus RTU
Alarm output: 2 sets of programmable Hi/Lo contacts with hysteresis setting, 5A/250VAC/30VDC
Cleaning relay: cleaning interval: 0.1-1000h, cleaning time: 1-1000s
Operating temperature: 0~70.0℃
Protection grade: IP65
Installation: panel / wall / pipe
Dimensions: External dimensions: 144 × 144 × 110mm, opening size: 138 × 138mm
Weight: about 0.85Kg
Order No.: 33-6801-50
innoSens 510 Fluoride Ion Electrode
The fluoride ion selective electrode is a solid-state thin-film electrode, the thin-film material is mainly LaF 3 single crystal, and a special polymer is at the periphery of the thin-film.
Measurement parameters: Fluoride ion concentration
Measuring range: 0.1-10000mg/L
Slope: 57±2mV/p F-ion
Response time: <30s
Stability: ±0.3mV(30min), ±1mV(24h)
Interfering ions: OH-(pH>8), formation of HF and HF2-(pH<5) interfering ions and fluoride ions ratio generates 10% error
pH range: 5-8pH
Operating temperature: 0-40°C
Sensitive film: LaF3 single crystal
Case material: black plastic
Size: 12mm diameter, 100mm length
Installation: flow-through tank/submerged installation, optional reference electrode required
innoSens 520 Chloride Electrode
The Chloride Ion Selective Electrode is a solid film electrode made of a high-strength AgCl/Ag 2 S pressed solid, which is subsequently sealed in a plastic body with resin.
Measurement parameters: Chloride ion concentration
Measuring range: 5-35000mg/L
Slope: 57±2mV/p Cl- ion
Response time: <30s
Stability: ±0.3mV(30min), ±1mV(24h)
Interfering ions: OH-/Cu2+/Br-/I-/CN-/Ag+/Hg2+/Pb2+/Ti+ in a certain proportion to produce 10% error
pH range: 1-10pH
Working temperature: 0-50℃
Sensitive film: AgCl/Ag2S
Shell material: black plastic
Size: 12mm diameter, 100mm length
Installation: Flow-through tank installation, optional reference electrode is required.