+44-203-7693048
Home / Products / ONLINE ANALYZER / Dissolved Oxygen / innoCon 6800O Online Dissolved Oxygen Analyzer

innoCon 6800O Online Dissolved Oxygen Analyzer

Measurement parameters


Dissolved Oxygen


Features

The latest wide power input, super anti-interference design
● Large-screen backlit LCD shows measured values, temperature and
relay status
● Chinese / English menu, easier to operate
● Password protection, to prevent unauthorized operation
● New calibration steps can help reduce operational errors
● 2 sets relay output can set High/ Low
● Automatic cleaning relay output
● 2 channel 4-20mA current
● RS485 Modbus output



Features
Product Model: innoCon 6800O
Measurement parameters: ppm/ppb dissolved oxygen
Measuring range: 0 -20.00mg/L,0 - 200%,0 - 200μg/L
Resolution: 0.01mg/L,0.1μg/L
Accuracy: ±1%f.s.
Temperature compensation: PT1000
Display: backlit large dot-matrix liquid crystal display
Language: Chinese/English
Password: Setting mode: 0022, calibration mode: 0011
Power supply: 90-260VAC,50/60Hz; 24VDC optional
Current output: 2 x isolated 4-20mA outputs, can set the measured value and temperature, maximum load 500Ω
Digital communication: RS485 Modbus RTU
Alarm output: 2 sets of programmable Hi/Lo contacts with hysteresis setting, 5A/250VAC/30VDC
Cleaning relay: cleaning interval: 0.1-1000h, cleaning time: 1-1000s
Operating temperature: 0~70.0℃
Protection grade: IP65
Installation: panel / wall / pipe
Dimensions: External dimensions: 144 × 144 × 110mm, opening size: 138 × 138mm
Weight: about 0.85Kg
Order No.: 33-6801-30

innoSens 420/425 polarographic dissolved oxygen electrode

JENSPRIMA's Clark Dissolved Oxygen Electrodes can only be used with the innoCon 6800O Dissolved Oxygen Controller.


innoSens 420 Dissolved Oxygen Electrode

Measuring range: 0-20mg/L, 0-200%.
Temperature compensation: PT1000
Operating Temperature: 0-60°C
Maximum pressure: atmospheric pressure
Flow rate requirement: ≥0.03m/s
Material: pps, gold/silver electrode
Installation method: submerged
Connection thread: 3/4 “NPT
Cable length: 10m as standard
Protection grade: IP68

Order No.: 35-0420-00


innoSens 425 Dissolved Oxygen Electrode

Measuring range: 0-200.00μg/L (ppb), 0-20.00mg/L (ppm)
Temperature compensation: PT1000
Operating Temperature: 0-60℃
Maximum pressure: atmospheric pressure
Flow rate requirement: ≥0.03m/s
Material: 316L stainless steel
Installation: Flow-through type
Connection thread: with circulation groove
Cable length: 10m as standard
Protection grade: IP68

Order No.: 35-0425-00


specifications

QUESTIONS? WE'RE HERE TO HELP.

CONTACT US
Search