PACON 5000 is a compact, easy-to-operate and high accuracy water quality analyzer for automatic on-line inspection of water quality residual hardness and quality control of water softening processes. This system controls the selectable limits based on the titration colorimetric principle, providing accurate measurement readings by extinction, and a variety of functions to ensure the reliability of real-time operation.
Low maintenance and low reagent consumption, suitable for long time continuous operation, maintenance-free, especially suitable for the pharmaceutical purified water and industrial boiler water testing.Select the alkalinity reagent to measure total alkalinity.
Measurement Parameters
Total Hardness
Total alkalinity
Application
Process Water
Water Treatment
Drinking Water
Cooling Water
General Specification
Measurement method: Titration method with colour change
Environmental temperature:5 - 45℃
Measuring water temp.:5 - 40℃
Water inlet pressure: ca. 0.5-5bar, recommended 1-2bar
Inlet / Outlet connect: 6mm hose
Requirements of the water quality:
clear,colourless,no solid particles,
without gas bubbles; pH: 4 - 10.5 ;
Iron: < 3 ppm ; Copper: < 0.2 ppm ;
Al: < 0.1 ppm ; Mn: < 0.2 ppm;
Humidity: 20 - 90% RH
Supply Voltage: 85 - 265VAC,47-63Hz
Power consumption: 25VA(in operation)
Dimensions: 300 x 300 x 200 mm (W x L x H)
Weight: ca.5Kg
Protection class:IP65
Installation: Wall mounting in closed rooms
Analysis Specification
Measurement range :The measurement range is defined by the reagent used. (see reagent table)
Measurement duration: ca. 3 minutes depending on the hardness of the water
Measurement accuracy: ±5% of the upper value of the respective reagent
Repetition accuracy: ±2.5% of the upper value of the respective reagent
Analysis cycle: Measuring interval(5 - 360min) /External signal
Flush time:15 - 1800s
Display: Multi-coloured and multi-lingual graphic display
Unit: mmol/l、 dH、mg/l、ppm CaCO3
Analogue output: 0/4~20mA,max. 750Ω
Interface: CAN bus
Relay output: 4x potential free output NC/NO, 250VAC/DC, 4A
Input: IN1: Start analysis, IN2:Cancel error
Order Guide
|
Order No. |
Description |
|
33-5000-00 |
PACON 5000 Online Hardness Analyzer |
|
33-5000-10 |
PACON 5000 Online Alkalinity Analyzer |
|
50-5000-10 |
Spare Parts Kit Including pump head (including pump tube), all seals, stirrups, connection pipe of reagent bottle, recommend to exchange every year.
|
|
50-5000-20 |
LED light source, recommended to be replaced every two years
|