+44-203-7693048
Home / Products / ONLINE ANALYZER / Streaming Current / Flumsys 10TC-SP Streaming Current Detector

Flumsys 10TC-SP Streaming Current Detector

The Flumsys 10TC-SP streaming current can be equipped with a pretreatment system to ensure the long-term trouble-free operation of the instrument, with continuous measurement, automatic cleaning,PH measurement and PID control function can be connected to the existing dosing system and start automatic dosing control. The amount of flocculant will be automatically adjusted according to the characteristics of the water.


Measured parameters
Streaming Current/SCD、pH

Applications
Waterworks、Sewage treatment plant、Sludge dewatering、Need to add flocculant process

Advantage
Automatic control of the dosing of flflocculant
cut costs、Maintain Water Quality
Low operating and maintenance costs
Real-time pH monitoring

Durable, reliable and easy to control dosing system


Water Quality Requirements
Conductivity:< 3000μS/cm
pH: 4~11pH (pH < 7 after controlled flflocculant application, SCD measurement is best)
TSS:< 1000mg/L
Features
● Simultaneous display of actual SC value and relative SC value
● Simultaneous pH monitoring (optional) for real-time knowledge of flocculation effects
● Automatic cleaning function
● PID control function
● SC 4-20mA and PID 4-20mA output
● 2 high/low alarm output
● RS485 Modbus RTU communication
● 4.3" colour touch screen, easy to operate
● Password protection to prevent unauthorized operation
● Data recording function, support U disk to export (Excel)
● Automatic control / manual control two modes
● Split sensor design for easy installation on site

● Optional pretreatment system, greatly reducing maintenance


Technical parameters

Measuring parameter:Streaming Current/SCD,pH
Measurement range:-1000~1000SC、0-14pH
Accuracy:±0.1%、±0.01pH
Repeatability:±0.1%
Response time:1s
Operating temperature:0-50℃
Liquid connection material:PTFE、POM、SS316
Housing:ABS/PC
Power supply:220VAC,50/60Hz
Analogue output:2 x 4-20mA (measured value and PID),max. load 500Ω
Relay output:2 high/low relays, alarm value and hysteresis can be set
Automatic cleaning:cleaning interval: 0-9999min, cleaning time: 0-999s
Digital communication:RS485 Modbus RTU
Data storage:Real time data recording, U disk export support (Excel format)
Sampling requirements:flocculant dosing point to sensor time about 3-5min
Flow rate requirement:1~4L/min
Protection class:IP65
Dimensions: Controller:Controller: 200×190×90mm, Sensor: 250×350×150mm 
Weight:Controller: ca.1Kg,Sensor: ca.5Kg


specifications

Order Guide

Order No.

Description

33-2310-61

Flumsys 10TC-SP

Streaming Current Detector

33-5510-11

Cleaning solenoid valves

33-5510-12

Filters

33-5510-10

PTFE kit

35-0125-10

innoSens 125T pH/TSensor