multi parameter water quality analyzer
HOME PARAMETERS Hot Products FlumPANEL 2501 Free and Total Chlorine Analyzer China Factory Suppliers


FlumPANEL 2501 Free and Total Chlorine Analyzer China Factory Suppliers
FlumPANEL 2501 Free and Total Chlorine Analyzer China Factory Suppliers

FlumPANEL 2501 Free and Total Chlorine Analyzer China Factory Suppliers

FlumPANEL 2501 Free Chlorine and Total Chlorine Analyzer features an integrated mounting design with a 4.3-inch color LCD touch screen. As leading China factory suppliers, we provide high-precision online water quality monitoring for industrial and municipal use.



Product Features:

The FlumPANEL 2501 is a high-precision Free Chlorine and Total Chlorine Analyzer designed for rigorous online water quality monitoring. Engineered for stability and accuracy, this industrial-grade instrument ensures optimal disinfection levels in water treatment processes, preventing both under-chlorination risks and chemical overdosing.

Utilizing advanced electrochemical sensing technology, the FlumPANEL 2501 provides real-time data acquisition and seamless integration into automated control systems. It is the ideal solution for municipal water plants, industrial wastewater treatment, and cooling tower management where stringent chlorine regulation is mandatory for safety and compliance.

Detailed Parameters

Measurement Range0.00 - 10.00 mg/L (Customizable) Measurement ParameterFree Chlorine / Total Chlorine
Accuracy± 2% of Full Scale Response Time< 60 Seconds
Output Signal4-20mA / RS485 Modbus Power Supply110V/220V AC 50/60Hz
Operating Temp5°C to 50°C Display TypeHigh-Contrast LCD / Digital Panel
Material BodyIndustrial Grade ABS/PVC Protection GradeIP65 / NEMA 4

Key Advantages

High Stability

Advanced drift compensation ensures long-term measurement stability and reduces the need for frequent recalibration.

Real-time Monitoring

Continuous online analysis provides instantaneous feedback for immediate dosing adjustments.

High Precision

Precision-engineered sensors deliver laboratory-grade accuracy in harsh industrial environments.

Intuitive Interface

Clear digital display and user-friendly menu for easy configuration and parameter setup.

Low Maintenance

Optimized flow cell design reduces reagent consumption and extends sensor lifespan.

Smart Integration

Supports Modbus and 4-20mA signals for seamless integration with PLC and SCADA systems.

Product Gallery

Management Platforms

Remote Monitoring

Access real-time chlorine levels from any location via cloud-based dashboards.

Automated Calibration

Simplified calibration workflows to maintain peak instrument accuracy with minimal effort.

Instant Alerting

Configure SMS or email notifications for abnormal chlorine concentrations or system faults.

Trend Analysis

Historical data logging for analyzing chlorine trends and optimizing chemical usage.

Dosage Control

Direct output signals to dosing pumps for precise, closed-loop chlorine injection.

Compliance Reporting

Automatic generation of water quality reports for regulatory environment submissions.

Investment Return Comparison

MetricManual TestingFlumPANEL 2501Benefit
Labor CostHigh (Daily Manual)Low (Automated)-70% Labor
Chemical WasteVariable/HighOptimized/Low-25% Reagents
Response TimeDelayed (Batch)InstantaneousReal-time Safety
Data AccuracyHuman Error ProneDigital PrecisionReliable Audit
Risk FactorHigh (Lagging)Low (Preventive)Risk Mitigation

Frequently Asked Questions

Q: What is the difference between Free Chlorine and Total Chlorine analysis?

Free chlorine is the amount of chlorine available to kill bacteria, while total chlorine includes both free and combined chlorine (chloramines). The FlumPANEL 2501 can be configured to monitor both to ensure maximum disinfection efficiency.

Q: How often does the sensor require calibration?

Depending on water quality and flow rates, calibration is typically recommended once every 2-4 weeks. The system features a simplified calibration process to minimize downtime.

Q: Can this analyzer be integrated into an existing PLC system?

Yes, the FlumPANEL 2501 supports standard industrial outputs including 4-20mA and RS485 Modbus, making it compatible with most PLC and SCADA platforms used in water treatment.

Q: Is the FlumPANEL 2501 suitable for wastewater applications?

Absolutely. It is designed for various water quality monitoring environments, including municipal drinking water, swimming pools, and industrial wastewater effluent monitoring.

Q: What reagents are required for the Total Chlorine measurement?

The Total Chlorine measurement requires specific DPD-based reagents. We provide high-purity reagent kits specifically optimized for the FlumPANEL series to ensure accuracy.

Q: How does the analyzer handle temperature fluctuations in the water?

The analyzer incorporates automatic temperature compensation to ensure that chlorine readings remain accurate regardless of the water temperature variation within the operating range.

Optimize Your Water Quality Monitoring Today

Contact Us

Datasheet Download




Online Message
We will manage and protect the privacy of the personal information
  • Name
  • E-Mail
  • Telephone
  • Message Content

Service Repair Form
Tell us what issue you encountered, including any steps or symptoms.
  • Name
  • Email
  • Phone
  • Fault Description

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.