multi parameter water quality analyzer
HOME PARAMETERS Hot Products InnoCon 6800O Dissolved Oxygen Controller China Factory Suppliers


InnoCon 6800O Dissolved Oxygen Controller China Factory Suppliers
InnoCon 6800O Dissolved Oxygen Controller China Factory Suppliers

InnoCon 6800O Dissolved Oxygen Controller China Factory Suppliers

Looking for reliable China suppliers? Our factory provides the InnoCon 6800O intelligent dissolved oxygen controller for water treatment and industrial monitoring, featuring Modbus RTU, temperature compensation, and versatile mounting options.



Product Features:

The InnoCon 6800O is a high-performance Dissolved Oxygen Controller engineered for precision monitoring and automated control in demanding water analysis environments. Designed to integrate seamlessly with professional-grade DO sensors, this controller ensures optimal oxygen levels in industrial wastewater treatment, aquaculture, and environmental monitoring systems, preventing hypoxic conditions and optimizing aeration efficiency.

Combining a robust industrial design with an intuitive user interface, the InnoCon 6800O transforms complex sensor data into actionable control signals. By maintaining strict adherence to dissolved oxygen setpoints, it helps operators reduce energy costs associated with aeration and ensures compliance with stringent environmental discharge regulations, making it an essential component for modern water quality management.

Detailed Parameters

Product ModelInnoCon 6800OParameter TypeDissolved Oxygen (DO)
Input SignalAnalog/Digital Sensor InputControl Output4-20mA / Relay Output
Display TypeDigital LCD InterfacePower SupplyStandard Industrial Voltage
Measurement Modemg/L or % SaturationControl LogicPID / On-Off Control
Mounting OptionPanel Mount / Wall MountCompatibilityInnoSensor DO Series

Key Advantages

Industrial Durability

Built with high-grade materials to withstand corrosive environments typical in chemical and water treatment plants.

Real-time Monitoring

Continuous sampling and rapid response times ensure that oxygen fluctuations are detected and corrected instantly.

High Precision

Advanced signal processing minimizes noise and interference, delivering laboratory-grade accuracy in the field.

Intuitive Display

Clear digital readouts and a user-friendly menu simplify calibration and setpoint configuration for operators.

Easy Calibration

Streamlined calibration workflows reduce downtime and ensure the sensor remains accurate over long periods.

Seamless Integration

Standardized outputs allow for easy connection to PLC, SCADA, or other centralized management platforms.

Product Gallery

Management Platforms

PLC Integration

Direct connection to programmable logic controllers for fully automated aeration cycles.

SCADA Compatibility

Centralized monitoring and data logging for large-scale water treatment facilities.

Alarm Management

Configurable high/low alerts to notify operators of critical oxygen depletion immediately.

Remote Telemetry

Support for remote data transmission to enable off-site monitoring of water quality.

Energy Optimization

Intelligent control of blowers to reduce electricity consumption based on real-time DO levels.

Maintenance Tracking

Digital logging of calibration dates to streamline sensor maintenance schedules.

Investment Return Comparison

Comparison FactorTraditional Manual ControlInnoCon 6800O System
Energy ConsumptionHigh (Constant Aeration)Low (Demand-Based)
Labor CostsFrequent Manual TestingAutomated Monitoring
Compliance RiskModerate (Sampling Gaps)Low (Continuous Log)
Equipment LifespanStandard WearExtended (Optimized Load)
Process StabilityFluctuating DO LevelsPrecise Steady-State

Frequently Asked Questions

Q: How does the InnoCon 6800O improve wastewater treatment efficiency?

By providing precise real-time dissolved oxygen data, the controller prevents over-aeration, which significantly reduces energy costs and prevents the disruption of biological treatment processes.

Q: Which sensors are compatible with this controller?

The InnoCon 6800O is specifically designed to work with the InnoSensor series of dissolved oxygen sensors, including both galvanic and optical types.

Q: Can this controller be integrated into an existing SCADA system?

Yes, the InnoCon 6800O features standard industrial outputs (such as 4-20mA), making it fully compatible with most SCADA and PLC systems for centralized control.

Q: How often does the system require calibration?

Calibration frequency depends on the water quality and sensor type, but the controller's simplified calibration menu allows for quick periodic adjustments to maintain accuracy.

Q: What happens if the dissolved oxygen levels drop below the setpoint?

The controller will trigger its configured output—such as closing a relay or increasing a 4-20mA signal—to activate blowers or aerators until the setpoint is reached.

Q: Is the InnoCon 6800O suitable for saltwater applications?

Yes, when paired with the appropriate salt-resistant DO sensors, the controller can effectively manage oxygen levels in brackish and saltwater environments.

Ready to Optimize Your Water Quality Control?

Contact Us

Datasheet Download




Online Message
We will manage and protect the privacy of the personal information
  • Name
  • E-Mail
  • Telephone
  • Message Content

Service Repair Form
Tell us what issue you encountered, including any steps or symptoms.
  • Name
  • Email
  • Phone
  • Fault Description

If you are interested in our products, you can choose to leave your information here, and we will be in touch with you shortly.