atically adjusted according to the characteristics of the water.
Waterworks、Sewage treatment plant、Sludge dewatering、Need to add flflocculant process
Streaming Current/SCD, pH
Advantage:
Durable, reliable and easy to control dosing system
Optional pretreatment system, greatly reducing maintenance
Measuring parameter:Streaming Current/SCD,pH
Accuracy: ±0.1% / ±0.01pH
Repeatability:±0.1%
Response time:1s
Operating temperature: 0-50℃
Liquid connection material:PTFE、POM、SS316
Housing:ABS/PC
Power supply:220VAC,50/60Hz
Analogue output:2 x 4-20mA (measured value and PID), max. load 500Ω
Relay output:2 high/low relays, alarm value and hysteresis can be set
Automatic cleaning:cleaning interval: 0-9999min, cleaning time: 0-999s
Digital communication:RS485 Modbus RTU
Data storage:Real time data recording, U disk export support (Excel format)
Sampling requirements:flflocculant dosing point to sensor time about 3-5min
Flow rate requirement:1~4L/min
Protection class:IP65
Dimensions: Controller:Controller: 200x190x90mm, Sensor: 250x350x150mm
Order Guide
Item no. Description
32-5510-20 Streaming Current Detector/ pH Analyzers,220VAC
33-5510-11 Cleaning solenoid valves
33-5510-12 Filters
33-5510-10 PTFE kit