The innoSens 451-RS fluorometric DO sensor is based on the fluorescence quenching principle, requires no membrane or electrode fluid, is virtually maintenance free, has excellent performance, is easy to use, does not consume oxygen and is widely used for DO monitoring in aeration basins of municipal water treatment plants and surface water.
Measured parameters
Dissolved oxygen, temperature
Applications
Sewage/wastewater treatment, surface water, aquaculture
Optical principle: no need to replace membrane and electrolyte, no flow rate required
Good fluorescent cap consistency and stability
Built-in optical attenuation compensation, long sensor life
Plug and play, easy to install
Technical parameters
Measurement range:0~20.00mg/L or 0~200%
Resolution:0.01mg/L
Accuracy:<±0.3mg/L
Repeatability:<±0.3mg/L
Response time:<45s
Supply power:12~24VDC
Communication: standard RS485 Modbus RTU protocol
Temperature compensation: Built-in NTC temperature probe
Operating temperature:0-50℃
Protection class:IP68
Mounting: Submerged installation
Cable length: 10m as standard
Material:POM+316L
Size:190mm
Weight:About 0.3kg
Order Guide
Order No. |
Description |
35-0451-10 |
innoSens 451,Fluorometric Dissolved Oxygen Electrode |
36-0451-10 |
innoSens 451-RS,Digital fluorometric dissolved oxygen electrode, RS485 Modbus RTU protocol
|